Skip to content

AR-UHS ultra-high-speed quenchant

Insufficient cooling? Identify the temperature interval first.

AR-UHS offers higher cooling intensity for workpieces requiring intensified quenching. Suitability depends on material, section and target microstructure, together with cracking and distortion control.

Company-measured cooling data

Compare Anran’s measured results directly

Select one record or show both. Temperature–time curves, cooling-rate–temperature curves and table values update together. The vertical axis is standard-probe temperature; the two horizontal axes show time and instantaneous cooling rate.

Combined dual-horizontal-axis cooling chart

The vertical axis is actual standard-probe temperature; the bottom axis is cooling time from 0–10 seconds; the top axis is instantaneous cooling rate from 0–300°C/s.

Bottom axis · Temperature–time pathTop axis · Rate–temperature path
2/2 records shown

Measured values

Test recordCharacteristic
temperature / °C
Characteristic
time / s
Temperature at
max rate / °C
Maximum rate
°C·s⁻¹
V300
°C·s⁻¹
t600
s
t400
s
t300
s
t200
s
21-01-07 20:23 / 1:2 / 20°C / relative motion (recorded parameter 1000)7990.10730298.592.30.81.82.74.3
21-01-07 20:27 / 1:2 / 20°C / no relative motion7820.10708285.297.50.81.82.64.0

Relative motion does not increase cooling equally at every temperature

Engineering application of an ultra-high-speed quenchant

Each record shows cooling performance under its stated test conditions. Our technical team advises on relative motion and operating conditions for your workpiece; this page does not derive a universal adjustment formula.

What to check before selection

Establish the cooling intervals required by the workpiece, then review concentration, bath temperature, relative motion and immersion conditions. Standard-probe results support medium comparison; actual internal cooling and the final condition still require workpiece-specific assessment.

Buy directly—simulation is not a prerequisite

AR-UHS is available independently. Request a quote if your requirements are clear, or describe the workpiece and insufficient cooling performance for technical advice.

Bath-fluid testers and workpiece temperature measurement systems are optional products, not conditions for purchasing AR-UHS.

Explore other products as needed

Every product can be quoted and purchased separately. Choose complementary products only when needed.

Ask directly about products and pricingAn email address and a short message are enough. Technical files are optional.

Data classification

Three data types must remain separate

Every curve and conclusion on this site is identified by how the data was obtained.

01 / MEASURED

Measured standard-probe cooling curves

Describes the medium response for the stated probe and test conditions. It is not the surface or core curve of a production workpiece.

02 / PREDICTED

Software-predicted curve

Calculated from a stated model and inputs. It is a prediction, not measured production data.

03 / WORKPIECE

Measured internal workpiece cooling curves

Comes from internal points in the actual workpiece and is used to assess the real cooling process against post-quench hardness, microstructure and properties.

Unless explicitly identified and validated, one data type cannot be converted into or substituted for another.Read the technical method